Oxygen 7Oxygen 7 - MONO MODULE
Pag. 14
7.1.6 INTERFACE PIN-OUT
SUB D 9P FEMALE
PIN DESCRIPTION DIRECTION
1 Ground GND
2 Talkback enable
IN
3 Duck control
IN
4
Emitter of photocoupler - Start B command OUT
5
Collector of photocoupler - Start B command OUT
6 + 6 V DC
OUT
7 Channel On/Off remote control
IN
8
Emitter of photocoupler - Start A command OUT
9
Collector of photocoupler - Start A command OUT
7.1.7 APPLICATIONS
CONTROLLING A MIC LIVE / ON AIR LAMP/DISPLAY
A mic/live display (On Air lamp as Mr Light) can be controlled in different ways. If you have only one mic
channel, the display can be controlled directly from the module remote interface, as described in 7.1.2. If you
have a number of mic channels, the display can be controlled from two Relays built-in in the Power Supply.
Two Jumpers (see § 7.6) allow to address the relays for this aim. Relay connections are provided in the PWS
Chapter.
The relays (and therefore the Mic/live display) are active when the module is ON (see the START mode
settings Jumpers FADER ÙÙ START and START ÙÙ FADER - § 7.7).
ENABLING TALKBACK
Talkback is used for off-air communication between:
- Studio and Control Room
- the presenter and the producer / sound engineer
- the presenter or the producer / sound engineer and the callers on the telephone line, etc
External talkback switch is connected between pins 2 and 6 of the remote connector.
The pre-fade input signal is fed to the T/B (to) CONTROL ROOM or to the T/B (to) STUDIO mix buses
depending on the TB Jumper configuration (see § 7.7) which also appear at the Studio/Control Room output
connectors (Monitor and Phones) on the Monitor Module.