Oxygen 7Oxygen 7 - AUDIO CONNECTIONS
Pag. 8
5 AUDIO CONNECTIONS
Matching the Console to Destination Equipment. The console produces a standard XLR output
level of 0dBu for a meter reading of ‘0’. It can produce a maximum of +23dBu and is therefore well suited to
driving equipment operating at nominal 0dBu or +4dBu while providing plenty of headroom. If you are
connecting directly to a sensitive power amplifier it is advisable to turn down its input trim control if the normal
console level is too high.
XLR FEMALE SOCKET (input)
Pin
1 Ground
2 In-phase (Hot)
3 Out-of-phase (Cold)
Short-circuit Pin 1 and 3 for unbalanced connections
XLR MALE SOCKET (output)
Pin
1 Ground
2 In-phase (Hot)
3 Out-of-phase (Cold)
Short-circuit Pin 1 and 3 for unbalanced connections
¼” JACK PLUG CONNECTORS FOR ‘B’ AND ‘TUNER’ INPUT SOCKETS
Pin
Ground Ground
Ring Out-of-phase (Cold) (-)
Tip In-phase (Hot) (+)
¼” JACK PLUG CONNECTORS FOR HEADPHONES SOCKETS
Pin
Ground Ground
Ring Right Channel
Tip Left Channel