Oxygen 7Oxygen 7 - TELCO MODULE
Pag. 40
9 TELCO MODULE
9.1 TELCO MODULE - REMOTE CONNECTOR
The 9 pin D-Type plug remote connector provides the inputs and outputs for the following functions:
Remote control for line ‘hooking’ on the external telephone hybrid
External control for RING LED (i.e. RING LED on the Telco module can be driven by a suitable external
command)
A 15 VDC current-limited output is also provided for use with the remote control outputs.
9.1.1 REMOTE INTERFACE PIN-OUT
SUB D 9P FEMALE
PIN DESCRIPTION DIRECTION
1 Ground GND
/
2 Not Connected
/
3 Not Connected
/
4 HOOK command - emitter of photocoupler
OUT
5 HOOK command - collector of photocoupler
OUT
6 + 6 VDC
OUT
7 External muting control
IN
8 External RING control - cathode of photocoupler
IN
9 External RING control - anode of photocoupler
IN
(console internal view)
9.1.2 DESCRIPTION
Pins 8 and 9 are used to make RING LED on the Telco module panel blinking when a call is coming in.
The remote interface photocoupler (pin 9 = Anode and pin 8 = Cathode) must be driven by an external suitable
command generated by external telephone hybrid. Typical current allowed: 5 mA (max 10 mA). Max voltage
allowed: 15 V.
A + 6VDC is provided on Pin 6 of interface.
The Oxygen 7’s Hook optoinsulator closes whenever ‘Hook’ button is pressed. Typical current allowed: max 10
mA. Max voltage allowed: 15 V.