Oxygen 7Oxygen 7 - MONO MODULE
Pag. 18
The same switch enables Remote Start A or B (see Remote Interface
description) accordingly to the selected Input. I.e. only one of the two
controls (Input A Start/Stop or Input B Start/Stop) will be active at any
time, depending upon the setting of the B SEL switch
7.6 REMOTE interface
This 9P SUB D FEMALE connector allows you to implement the following
facilities:
• START status input A
• START status input B
• External TB (Talk Back) enabling
• External START (ON-OFF) control
• DC DUCK control
The Connettors provides also +6VDC and GND conections.
Only one of the two Start commands (A or B) will be active at any time,
depending upon the setting of the B SEL switch (see)
Please refer to § 7.1 for interface connections.
This interface is suitable for Axel Technology’s DJ CONSOLE.
Thanks to it, the presenter (normally located in studio) is able to remotely
switch On/Off the Mono module. Moreover, through a mixer-like slider he
may fade the level of the on-air musical program (for speech interventions
mixed to the songs). A Talk Back enabling key is also provided to enable
private communications from Studio to Control Room.
Comments to this Manuals