7.13 MASTER-SUB1-SUB2 ROUTING SWITCHES
The input channel signal may be routed to the main Stereo MIX (L-R) or
pairs SUB busses 1 & 2 by pressing the respective switches.
The routing switchers work in conjunction with the module status (On or
Off)
There is a red LED next to each switch which will illuminate at two levels
of brightness.
The LED will illuminate at half brightness if the Switch is pressed but the
module is Off.
You may regard this as the routing circuit being armed but not active.
To make it active the On status must be engaged (see § 7.16). The LED
will illuminate at full brightness to indicate that the circuit is now active.
When one or more routing switchers are depressed, LED is off and the
routing circuit is never active, regardless of the module status (On/Off).
LED OFF
switch depressed / the status of the module
doesn’t affect routing circuit
LED ON
switch pressed / routing circuit is active as the
module is On
LED HALF
BRIGH.
switch pressed / routing circuit is non active as
the module is Off
This three mode operating has been introduced in order to prevent buss
from additional noise when routing switchers are pressed and module is
off.
The Sub mix can be mixed into the main output mixbuss in the master
section (see Master routing switcher on the Sub modules).
This is a convenient way to use the SUB assigment switch as a su/jointfilesconvert/268126/bgroup
system, creating new possibilities in the Oxygen 7 console.
7.14 DUCK SWITCH
The Duck is an ON/OFF switch which tells each VCA fader whether or not
they partecipate in the external Duck control.
Please ref to Chapter 6.
The DUCK switcher works in conjunction with the module status (On or
Off)
There is a red LED next to the switch which will illuminate at two levels of
brightness.
The LED will illuminate at half brightness if the switch is pressed but the
module is Off.
You may regard this as the DUCK routing circuit being armed but not
active.